I. Repairable Culpa Genera
Finem faciem contaminationem
Symptomata: infirma / instabilis optical signum, oleum maculis et fingerprints in finem faciem tuam
Actio:
Uti alimentorum fibra opticus Purgato virga in unum directionem (ne uti circulares motibus).
Nam pertinax maculas, tingite in anhydrous ethanol, dab suaviter, et ictu siccum.
Contraindications: Noli uti bombacio swabs vel charta mantilibus (fibra residue est de).
Casting damnum
Symptomata: et iaccam est scissa, sed in fibra core integrum.
Actio:
Cut off laesis sectionem, adhibere duplex murus calor shrink Tubing et calor aequaliter cum calor gun.
Nam armis patch funibus, crimp et sigillum cum immaculatam ferro reparatione Tubing.
Clip rumpitur
Symptomata: et LC / SC plastic clip victus est.
Actio: Replace with a metal-shelled connector of the same model (re-termination is required).


II. Unrepairable dura delicta
Abiicias statim. Signa:
Fiber Core Breakage (Nigrum maculis cum Illuminated a rubrum lux stylo)
Ceramic Ferrule chipping / Cracks (visibilis in microscopio)
COPULARIUS Greenh Postquam aqua nuditate (oxidized aeris components)
Unum fibra in MPO Draconis funis est deficit


III. Quattuor gradum Iungo replacement modum
Tools Requiritur: Fiber strippers, Cleaver, epoxy resinae, abrasive chartam
Fibra finem remotionem, interficiam off laedantur finem, relicto saltem 15cm of excess fibra. Draconis 3cm de exterioribus iaccam et mundus fibra core cum Vocatus extergimus. Thread novam iungo. Inserere nudis fibra in novam LC / SC Ceramic manica. Inject hyacintho epoxy resinae et remedium pro XXX minutes. Accipiens Celebratio: Usus fibra Cleaver ad directe removere excessus fibra core. Cross-section debet protre ≤0.5mm ex sleeve. Finem faciem politicas
Tres-gradum molere:
Crassius molere (trahere an "VIII" figura X temporibus cum 12μm Sandpaper)
Denique molere (trahere an "VIII" figura XX temporibus per 3μm Sandpaper)
Microscopic examen (no scalpit in 200x microscopium)


IV. Nolite scriptor et Don'ts

Operatio iniuria Consecutio Bene alternative Critica
Calidum, plugging sine verificationem Ardet optical module circuits Power off Equipment & Quin shutdown (Fatalem)
Tangens ferrules nudum digitos Cutis olea corrode anti-reflective coating Gerunt Lint, liberum caestus vel usu vacuum tweezers (Gravi)
Using tenaces tape in connectors Tenaces seeps in optical iter clausus lux Install OEM pulvis caps statim (High)
Expolia fibra cum axicia Speculum shards embed in cute / oculis Uti precision fibra strippers (E.G., Miller) (Gravi)


V. Amet post-reparatione probat
Rubrum lux in / off. Acceptabile si non tenebris maculis praesens per totam sectionem (praesertim ad flectit).
Test damnum
Comparari ad officinas values: una-modus ≤0.5DB / Multi-Modus ≤0.8DB.
Tormentis probat
Tollens: ponere a 1kg trahere ad X seconds (nullum signum intermissione).
Torquens: Torquent utrumque terminum CLXXX ° (damnum fluctuation <0.3db).
Tendentes: Circumda circum leviora (exterius diameter 3cm) ter.